- ÃøÁ¤ ¶óÀÎ : ´Ü»ó±³·ù£¬»ï»ó
- ÃøÁ¤ Ç׸ñ : Àü¾Ð£¬Àü·ù£¬Àü¾Ð/Àü·ù ÇÇÅ©£¬À¯È¿/Ç¥¸é/¹«È¿ Àü·Â£¬¿ª·ü£¬À§»ó °¢£¬¹«È¿À²£¬ÁÖÆļö£¬Àü¾Ð/Àü·ù °íÁ¶ÆÄ
- ÃøÁ¤ ·¹ÀÎÁö : - Àü¾Ð; 150.0 ~ 600V 3 ranges - Àü·ù; 20.0 ~ 1000A 3 ranges - Àü·Â; 3.000kW¡1200.0kW (Àü·ù¡¤Àü¾Ð ·¹ÀÎÁöÀÇ Á¶ÇÕ¿¡ ÀÇÇÏ´Ù)
- Àü¾Ð È®µµ : ¡¾1.0 % rdg. ¡¾3 dgt - Àü·ù È®µµ : ¡¾1.3 % rdg. ¡¾3 dgt. (at 45 to 66 Hz) - Àü·Â È®µµ : Power/single-phase: ¡¾2.3 % rdg. ¡¾5 dgt., Power/3-phase: ¡¾3.0 % rdg. ¡¾10 dgt. (at balanced load)
- Ç¥½Ã°»½Å ·¹ÀÌÆ® : NORMAL ¾à 1 ȸ/s£¬SLOW ¾à 1 ȸ/3s£¬°íÁ¶ÆÄ ÃøÁ¤ ½Ã¾à1 ȸ/2s
- ÁÖÆļö Ư¼º¡¡: AC Àü·ù (45 to 1 kHz), AC Àü¾Ð (30 to 1 kHz) - ÀÎÅÍÆäÀ̽º : RS-232C(¿É¼Ç 9442 ÇÁ¸°ÅÍ¿¡ ÀÎÀÚ Ãâ·Â °¡´É)
- ±â´É : °Ë»ó£¬·¹Äڵ壬µ¥ÀÌÅÍ È¦µå£¬¿ÀÅä ÆÄ¿ö ¿ÀÇÁ£¬ÀüÁö Àܾç Ç¥½Ã£¬ÇÁ¸°ÅÍ Ãâ·Â
- ÃøÁ¤ °¡´É µµÃ¼°æ : ¥õ55mm ,80mmX20mm busbar max.
- Àü ¿ø : ÀûÃþÇü ¾ËÄ®¸® °ÇÀüÁö(6LR61)¡¿1(¿¬¼Ó »ç¿ë ¾à25h) - ¶Ç´Â ÀûÃþÇü ¸Á°£ °ÇÀüÁö(6F22)¡¿1(¿¬¼Ó »ç¿ë ¾à10h)
- Ä¡¼ö¡¤Áú·® : 100 mm(3.94 in)W ¡¿ 287 mm(11.3 in)H ¡¿ 39 mm(1.54 in)D, 650 g (22.6 oz)
- ºÎ ¼Ó Ç° : 9635 Àü¾Ð ÄÚµå 1£¬9245 ÈÞ´ë¿ë ÄÉÀ̽º 1£¬ÇÚµå °¡Áײö 1
Measurement lines |
Single-phase/two-wires, Three-phase/three-wires (balanced load only) |
Measurement items |
Voltage, current, voltage/current peak, effective/reactive/apparent power(Single-phase or 3-phase), power factor, reactivity, phase angle, frequency, phase detection(3-phase), voltage/current harmonic levels(up to 20th) |
Measurement ranges |
Voltage: 150.0 V to 600 V, 3 ranges, Current: 20.00 to 1000 A, 3 ranges, Power: 3.000 kW to 1200 kW, 18 combination patterns, Note: 3-phase power is calculated and displayed on the basis of a balanced, 50/60 Hz, sine wave input. For apparent power and reactive power, the unit of watts in the above table is replaced by VA and var respectively. |
Basic accuracy at 50/60 Hz, COS ¨ª=1 |
Power/single-phase: ¡¾2.3 % rdg. ¡¾5 dgt., Power/3-phase: ¡¾3.0 % rdg. ¡¾10 dgt. (at balanced load) |
Voltage / Current accuracy |
Voltage: ¡¾1.0 % rdg. ¡¾3 dgt., Current: ¡¾1.3 % rdg. ¡¾3 dgt. (at 45 to 66 Hz) |
Frequency characteristics |
AC current : 45 to 1 kHz AC voltage : 30 to 1 kHz |
Other functions |
Phase detection, Record (Max. value/Min. value), Battery capacity display, Data hold, Auto power off, Data output (RS-232C interface by optical insulating coupler) |
Display update rate |
NORMAL: approx. 1 time/ sec, SLOW: 1 time/ 3-sec, HARM meas.: approx. 1 time/ 2-sec |
Power supply |
6LR61 alkaline battery ¡¿ 1 (continuous operation max. 25 hours), 6F22 manganese battery ¡¿ 1 (continuous operation max. 10 hours) |
Dimensions, mass |
100 mm(3.94 in)W ¡¿ 287 mm(11.3 in)H ¡¿ 39 mm(1.54 in)D, 650 g (22.6 oz) Core jaw dia.: ¨ª55 mm(2.17 in) or 80 mm (3.15 in) ¡¿ 20 mm (0.79 in) busbar |
Accessories |
VOLTAGE CORD 9635 (1), CARRYING CASE 9245, (1), Hand strap (1) | | |