»óÇ° ¿É¼Ç
»óÇ°¸í
Fluke 355, AC/DC µðÁöÅÐŬ·¥ÇÁ¸ÞŸ(50mm)
ÆǸŰ¡
1,410,000won
¹è¼Û
100,000¿ø ÀÌ»ó ¹«·á¹è¼Û (ÁÖ¹® ½Ã °áÁ¦)
Á¦Á¶»ç
FLUKE
¿ø»êÁö
china
·»Å»¾È³»

°í-Àü·ù ÃøÁ¤±â´É°ú Ä¿´Ù¶õ Áý°Ô¸¦ °¡Áö°í ÀÖ¾î »ê¾÷ ºÐ¾ß ¹× ¼³ºñ ¾îÇø®ÄÉÀ̼ǿ¡ ÀûÇÕÇÏ°Ô
µðÀÚÀÎµÈ Å¬·¥ÇÁ¸ÞŸÀÔ´Ï´Ù.

Ture-RMS·Î ½Å·Ú¼ºÀÖ´Â ÃøÁ¤ÀÌ °¡´ÉÇÑ Fluke 355/353 Ŭ·¥ÇÁ¸ÞŸ´Â 2000A±îÁöÀÇ Àü·ù ÃøÁ¤À»
À§ÇØ ¼±ÅÃÇÒ ¼ö ÀÖ´Â ÀåºñÀÔ´Ï´Ù.   ÀϹÝÀûÀ¸·Î °í-Àü·ù ¾îÇø®ÄÉÀ̼ǿ¡¼­ ¹ß°ßÇÒ ¼ö ÀÖ´Â ±½Àº
ÄÉÀÌºíµµ ½±°Ô ÃøÁ¤ÇÒ ¼ö ÀÖµµ·Ï Ä¿´Ù¶õ Àåºñ¸¦ °¡Áö°í ÀÖ½À´Ï´Ù.     ¶ÇÇÑ °í-Àü·ÂÀ» ÃøÁ¤ÇÒ ¶§
»ç¿ëÀÚ º¸È£¸¦ À§ÇÑ °ß°íÇÑ µðÀÚÀΰú   CAT IV 600V,  CAT III 1000V  ¾ÈÀü µî±ÞÀÌ  Ưº°È÷  Ãß°¡
µÇ¾ú½À´Ï´Ù. 


Ư¡


- 2000A ac+dc true-rms, 1400A ac, 2000A dc·Î ½Å·Ú¼º ÀÖ°Ô ÃøÁ¤
- 50mmÀÇ Å« Áý°Ô·Î Å©°í ´Ù¾çÇÑ ÄÉÀÌºí¿¡ ÀûÇÕ
- »ç¿ëÀÚ º¸È£¸¦ À§ÇÑ CAT IV 600, CAT III 1000V ¾ÈÀüµî±Þ
- ÃÖ¼Ò, ÃÖ´ë, Æò±Õ ±â´É
- µð½ºÇ÷¹ÀÌ È¦µå ±â´É


Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 §Ù Resolution: 0.1 §Ù
Accuracy: 1.5 % + 5 digits
Range: 4 k§Ù Resolution: 1 §Ù
Accuracy: 1.5 % + 5 digits
Range: 40 k§Ù Resolution: 10 §Ù
Accuracy: 1.5 % + 5 digits
Range: 400 k§Ù Resolution: 100 §Ù
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
  On at ¡Â 30 §Ù
  Off at ¡Ã 100 §Ù
Frequency measurement
Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables

*Add 2 % to error spec for CF > 2

General specifications
Batteries
  Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
  100 hours
Test leads
  Rated to 1000 V
Weight
  .814 kg (1.8 lb)
Jaw size
  58 mm (2.28 in)
Dimensions (LxWxD)
  300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating
  IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Environmental specifications
Operating temperature
  32 ¡ÆF to + 122 ¡ÆF (0 ¡ÆC to +50 ¡ÆC)
Storage temperature
  -4 ¡ÆF to 140 ¡ÆF (-20 ¡ÆC to +60 ¡ÆC)
Operating humidity
  0 to 95 % (non-condensing)
Operating altitude
  2000 m
Storage altitude
  10,000 m
IP rating
  42 (indoor use only)
Drop test requirements
  1 m
EMI, RFI, EMC
  FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current: 0.1 % of reading per ¡ÆC outside 22 ¡ÆC to 24 ¡ÆC
Voltage: 0.1 % of reading per ¡ÆC outside 22 ¡ÆC to 24 ¡ÆC

review ÀÛ¼º Æû
review board
ÀÌ ¸§ :
ÆòÁ¡ :      
³» ¿ë :

COMMENT

+ MORE

review ¸®½ºÆ®
NO
SUBJECT
SCORE
NAME
DATE

REVIEW

review ¸®½ºÆ®
µî·ÏµÈ ¸®ºä°¡ ¾ø½À´Ï´Ù.

Q&A

QnA ¸®½ºÆ®
µî·ÏµÈ ¹®ÀÇ°¡ ¾ø½À´Ï´Ù.

À§·Î°¡±â

Item size chart »çÀÌÁî ±âÁØÇ¥

¡Ø »óÇ°»çÀÌÁî Ä¡¼ö´Â Àç´Â ¹æ¹ý°ú À§Ä¡¿¡ µû¶ó 1~3cm ¿ÀÂ÷°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.

ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â