¢Ã True RMS value (V and A)
¢Ã Leakage Current Measurement at 10 §Ë Resolution
¢Ã Harmonic Analysis (V and A) to the 99th Order
¢Ã Better Understanding of High Frequency harmonic Analysis (Up to 5/6kHz)
    (5/6kHz±îÁöÀÇ ³ôÀº ÁÖÆļöÀÇ °íÁ¶Æĸ¦ ½±°Ô Æǵ¶ °¡´É )
¢Ã Non Interupted Harmonic Analysis (°£¼· ¹ÞÁö ¾Ê´Â °íÁ¶ÆÄ ºÐ¼® °¡´É)
¢Ã Analysis of Total Harmonic Distortion (THD-F)(°íÁ¶ÆÄ ¿Ö°î ÇÕ°èÄ¡ ºÐ¼®)
¢Ã Analysis of Crest Factor (C.F.)
¢Ã Fast peak Function (33§Á and 39§Á)
¢Ã Programmable CT Ratio (1 to 250)

¢Ã W, KW, Hp
¢Ã VA, KVA, VAR, KVAR
¢Ã PF, Phase Angle (¥Õ)
¢Ã Energy (mWH, WH, KWH)
¢Ã Analysis of Standby Power Consumption
¢Ã Balanced 3¥Õ Power Quality
¢Ã Balnced 3¥Õ Seqence

¢Ã AC Watt (50-60Hz, PF=0.5 to 1, CT=1,Accuracy of Readings)

Range

Resolution

Accuracy21 (0-30A)
Accuracy23 (0-60A)

Accuracy21 (30-50A)
Accuracy23 (60-100A)

0.000-9.999W

0.001W

¡¾0.1% ¡¾0.02W

¡¾0.2% of VA ¡¾5digits

10.00-99.99W

0.01W

¡¾0.1% ¡¾0.2W

¡¾0.2% of VA ¡¾5digits

100.0-999.9W

0.1W

¡¾0.1% ¡¾0.02W

¡¾0.2% of VA ¡¾5digits

1.000-9.999kW

0.001KW

¡¾0.1% ¡¾0.002KW

¡¾0.2% of VA ¡¾5digits

10.00-99.99kW

0.01KW

¡¾0.1% ¡¾0.02KW

¡¾0.2% of VA ¡¾5digits

100.0-999.9kW

0.1W

¡¾0.1% ¡¾0.2KW

¡¾0.2% of VA ¡¾5digits

1000-9999kW

1KW

¡¾0.1% ¡¾2KW

¡¾0.2% of VA ¡¾5digits

 

¢Ã AC Current (50 or 60 Hz, True RMS)

Range (Model 21)

Range (Model 23)

Resolution

Accuracy of Reading

0.30-60.00mA

0.30-60.00mA

0.01mA

¡¾0.5% ¡¾5digits

60.0-600.0mA

60.0-600.0mA

0.1mA

¡¾0.5% ¡¾5digits

0.030-3.000A

0.300-9.999A

0.001A

¡¾0.5% ¡¾5digits

3.00-30.00A

10.00-60.00A

0.01A

¡¾0.5% ¡¾5digits

30.00-50.00A

60-99.99A

0.01A

¡¾1.0% ¡¾5digits

 

¢Ã AC Voltage (50 or 60 Hz, True RMS)

Range

Resolution

Accuracy (%)

Accuracy of R.

3V - 250V

0.1V

¡¾ 0.5%

¡¾0.5% ¡¾ 5digits

250V-600V

0.1V

¡¾ 0.5%

¡¾0.5% ¡¾ 5digits

 

¢Ã Harmonics of AC Voltage in % and Magnitude (1 to 99th order)

Range

Resolution

Accuracy (%)

Resolution

Accuracy of R.

10.00-60.00mA

0.1%

¡¾0.5% ¡¾ 5 digit

0.01mA

¡¾0.5% ¡¾ 0.1mA

 

¢Ã Harmonic of ACA in % and Magnitude (1 to 99th order)

Range
(Model 21)

Range
(Model 23)

Res.

Accuracy
(%)

Res.

Accuracy
of R.

10.00-60.00mA

10.00-60.00mA

0.1%

¡¾0.5%¡¾5digit

0.01mA

¡¾0.5%¡¾0.1mA

60.0-600.0mA

60.0-600.0mA

0.1%

¡¾0.5%¡¾5digit

0.1mA

¡¾0.5%¡¾0.1mA

0.030-3.000A

0.5-9.999A

0.1%

¡¾0.5%¡¾5 digit

0.001A

¡¾0.5%¡¾0.1mA

0.5-30.00A

10.00-60.00A

0.1%

¡¾0.5%¡¾5 digit

0.01A

¡¾0.5%¡¾0.1mA

30.00-50.00A

60-99.99A

0.1%

¡¾1.0%¡¾5 digit

0.1A

¡¾0.5%¡¾0.1mA

 

¢Ã Power Factor & Phase Angle

Ç׸ñ

Range

Resolution

Accuracy

Power Factor

0.000 - 1.000

0.001

¡¾ 1¡Æ

Phase Angle

-180 to 180 (0 to 360)

1¡Æ

¡¾ 1¡Æ

 

¢Ã THD-F (1 to 99th order) & Crest Factor

Ç׸ñ

Range

Resolution

Accuracy

THD

0.0 - 999.9%

0.1%

¡¾0.5% ¡¾5 digits

Crest Factor

250V-600V

0.001

¡¾0.5% ¡¾30 digits

 

¢Ã Physical Specification

- Conductor Size : 30mm max. (approx.)
- Display : 4+4+2 Digital LCD
- Range Selection : manual
- BatteryType : two 1.5V SUM-3
- Power Consumption : 5mA (approx)
- Auto-Power off function: Yes
- No of Samples Period : 512 (V & A), 256(W)
- Operating Temperature : -10¡É to 50¡É
- Operating Humidity : less than 85% relative
- Storage Temperature : -20¡É to 60¡É
- Storage Humidity : less than 75% relative
- Dimension : 210mm (L) x 62.0mm (W) x 35.6mm (H)
- Weight : 200g (battery Included)
- Accessories : Carrying bag, Users manual, 1.5V batteries, Test Leads

 

¢Ã Option : Alligator Clips

review ÀÛ¼º Æû
review board
ÀÌ ¸§ :
ÆòÁ¡ :      
³» ¿ë :

COMMENT

+ MORE

review ¸®½ºÆ®
NO
SUBJECT
SCORE
NAME
DATE

REVIEW

review ¸®½ºÆ®
µî·ÏµÈ ¸®ºä°¡ ¾ø½À´Ï´Ù.

Q&A

QnA ¸®½ºÆ®
µî·ÏµÈ ¹®ÀÇ°¡ ¾ø½À´Ï´Ù.

À§·Î°¡±â

Item size chart »çÀÌÁî ±âÁØÇ¥

¡Ø »óÇ°»çÀÌÁî Ä¡¼ö´Â Àç´Â ¹æ¹ý°ú À§Ä¡¿¡ µû¶ó 1~3cm ¿ÀÂ÷°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.

ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â