digimess¢ç expert / order No. : H.UC 15-00


Three counting channels
  Channel A and B - 10§Ô to 100M§Ô
  Channel C - 50M§Ô to 2.4G§Ô
High input sensitivity of ¡Ã 25 mV and a time base accuracy of 10
-8
over 24 hours
Frequency ratio measurement - Channel A and B / channel C and B
Period length measurement - channel A (Measuring range : 1¥ìs to 100ms)
Time interval measurement - Channel A and B (Measuring range : 1¥ìs to 100s)
Pulse counting - Channel A or B (Measuring range : 1 to 10
9
events)
Memory function
Self-diagnostics check
RS-232C/IEEE 488.2 interfaces
Radio interference suppression - EN55011 Class B
Safety class -¤Ó according to EN61010 Part 1
  • Technical Data

Characteristics of channel A and B

Frequency range 10 Hz - 100 MHz
Basic sensitivity Vrms= 25 mV (sinusoidal signal)
V
pp= 75 mV with pulses of minimal width 10ns
Input coupling AC
Input impedance 1§Û (< 40pF)
Input divider 1:1 or 10:1
Dynamic range with divider 10:1 75mV¡ÂVpp ¡Â 5V
750mV¡ÂV
pp ¡Â50V
Maximum input voltage 50V(DC+ACpeak)with divider 10:1,
8 V (V
rms ) with divider 1:1, f > 100 kHz
Trigger edge rising or falling
Trigger level setting
Voltage divider 1:1
Voltage divider 10:1
adjustable via potentiometer
- 1.5V to +1.5V
- 15V to +15V

Characgeristics of channel C
Frequency range 50MHz to 2400MHz
Division ratio 100:1
Sensitivity Where:
f=50-100M Hz
f=100 MHz - 2GHz
f=2-2.4GHz
Vrms= 50mV
V
rms
= 25mV
V
rms= 50mV
Input impedance 50§Ù
Input coupling AC
Maximum input voltage Vrms= 2.5V (sinusoidal signal) ¡¾ 40V DC voltage content
  • Measuring Functions
Self-diagnostics check (CHECK)
Measuring range 10MHz (Frequency standard)
Gate time tgate = 10¥ìs, 100¥ìs, 1ms, 10ms, 100ms, 1s, 10s
Accuracy ¡¾1 LSD1)
Display of results M Hz with decimal point

 

Frequency measurement on channel A or B(FREQ A, FREQ B)
Measurement range 10Hz to 100MHz
Gate times tgate = 10¥ìs, 100¥ìs, 1ms, 10ms, 100ms, 1s, 10s
Frequency resolution f=1/tgate(max of 9 digits)
Accuracy ¡¾1 LSD1) ¡¾ time base error
Results display Hz, kHz, MHz with decimal point

Frequency measurement over channel C (FRC)
Measurement range 50MHz to 2.4GHz
Gate times tgate = 10¥ìs, 100¥ìs, 1ms, 10ms, 100ms, 1s, 10s
Frequency resolution f=100/tgate(max. of 9 digits)
Accuracy ¡¾1 LSD1) ¡¾ time base error
Results display MHz, GHz, with decimal point

Measurement of frequency response ratios over channels
A and B (RAT A/B)
Inputs channels A and B(Vrms¡Ã100mV for channel B)
Measuring range 10-7 to 107
Gate times 102 to 108 times the period of the input signal of channel B
Frequency resolution
1/n
Accuracy ¡¾1 LSD1) ¡¾ trigger error of channel B
Display of results without unit of measurement, with decimal point

Measurement of frequency response ratios over channels A and C (RAT A/C)
Inputs channels C and B(Vrms¡Ã100mV for channel B)
Measuring range 0.5 - 2.4 ¡¿ 108
Gate times 102 to 108 times the period of the input signal of channel B
Frequency resolution
100/n
Accuracy ¡¾1 LSD1) ¡¾ trigger error of channel C
Display of results without unit of measurement, with decimal point

Period measurement over channel A or B (PER A, PER B)
Measuring range 1 ¥ìs to 100ms
Sensitivity Vrms=100mV
Unit of measurement(resolution)
100ns
Accuracy ¡¾1 LSD1) ¡¾ trigger error ¡¾time base error
Display of results ¥ìs, ms, s with decimal point

Measurement of time interval over channel A and B (TIME AB)
Measuring range 1 ¥ìs to 100s
Signal rise > 6 V/s
Unit of measurement(resolution)
100ns
Accuracy ¡¾1 LSD1) ¡¾ trigger error ¡¾time base error
Display of results ¥ìs, ms, s with decimal point

Pulse count over channel A or B (TOT A, TOT B)
Measurement range 1 to109 events
Sensitivity Vrms= 100mV(in the case of external trigger)
Signal rise > 6 V/s
Accuracy of the external control
Counter error
Measuring interval error
¡¾1 LSD1)
¡¾ trigger error
Display of results

Time base
Warm-up time 15min.
Nominal frequency of crystal 10MHz
Frequency setting accuracy ¡¾5 10-9
Frequency deviation after 24 hours ¡Â¡¾10-8
Influence of temperature ¡Â¡¾5 ¡¿ 10-9/¡Æc

Environmental conditions
Nominal temperature + 23 ¡ÆC ¡¾ 2 ¡ÆC
Operating temperature + 5 ¡ÆC... + 40 ¡ÆC
Relative humidity 20 to 80%
Atmospheric pressure 86 to 106 kPa
Interference suppression Vfg.1046-1984,VED0871 CategoryB
Dimensions and weights
Dimensions (W ¡¿ H ¡¿ D)
Dimensions of packing (W ¡¿ H ¡¿ D)
290mm ¡¿ 120mm ¡¿ 260mm
335mm ¡¿ 125mm ¡¿ 385mm
Weight of universal counter
Weight inc. packing and accessories
approx. 3.8kg
approx. 6.0kg

Power supply
Operating voltage Sinusoidal AC voltage (distortion factor < 5%)
115/230V (+10%/-15%), switchable internally,47 to 63Hz
Power consumption 40VA
Fuses T125L/250V (230V~)
T250L/250V (115V~)
Safety class 1 according to EN61010,corresponds to DIN VDE0411 Part 1 1993

Accessories supplied with the package
-Mains cable -Operating instruction
-2¡¿BNC-BNC cables -Spare fuses

Accessories supplied with the package
The counter can be fully controlled and can be read out via the parallel GPIB and the serial interface RS-232C apart from the setting of the trigger levels.
review ÀÛ¼º Æû
review board
ÀÌ ¸§ :
ÆòÁ¡ :      
³» ¿ë :

COMMENT

+ MORE

review ¸®½ºÆ®
NO
SUBJECT
SCORE
NAME
DATE

REVIEW

review ¸®½ºÆ®
µî·ÏµÈ ¸®ºä°¡ ¾ø½À´Ï´Ù.

Q&A

QnA ¸®½ºÆ®
µî·ÏµÈ ¹®ÀÇ°¡ ¾ø½À´Ï´Ù.

À§·Î°¡±â

Item size chart »çÀÌÁî ±âÁØÇ¥

¡Ø »óÇ°»çÀÌÁî Ä¡¼ö´Â Àç´Â ¹æ¹ý°ú À§Ä¡¿¡ µû¶ó 1~3cm ¿ÀÂ÷°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.

ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â